The circuit-board repairs explained in the previous parts resolved most of the problems I described—more than 80% in my experience.
The main point I wanted to share is that, if you have some basic technical and soldering skills, it may be possible to repair the opener yourself for less than NZ$100 instead of spending more than NZ$1,000 to replace the entire unit.
I have also seen openers with failed motors or damaged gearboxes. Unfortunately, these faults are generally much more difficult to repair. One possible solution is to purchase a second-hand opener and use its motor or gearbox as a replacement. You could also install a complete working second-hand opener.
However, because these openers are already quite old, the replacement unit may eventually develop the same circuit-board problems and require similar repairs.
In this part, I will explain two additional faults I have encountered that were not directly caused by the main circuit board.
1. Faulty Motor Run Capacitor
After removing the opener’s metal cover, you will find the motor run capacitor in the location shown in the picture below.
If you have completed the circuit-board repair but the opener is still not operating correctly, I recommend checking and, if necessary, replacing this capacitor.
The original capacitor fitted to my opener had the following specifications:
- Capacitance: 12 µF
- Tolerance: ±5%
- Voltage rating: 250 V AC
The original capacitor is shown in the picture below. An identical 250 VAC replacement may be difficult to find.


Instead, you can search AliExpress or eBay using the following description:
12 µF CBB61 air-conditioning fan capacitor, 450 V AC, 4-pin, 50/60 Hz
A capacitor rated for 450 V AC can be used in place of the original 250 V AC capacitor, provided that it is a suitable AC motor-run capacitor with the same 12 µF capacitance and compatible connections.
The picture below shows the replacement capacitor I purchased. It was physically larger than the original capacitor, but I was able to install it without any problems.
*Symptoms of a Faulty Motor Run Capacitor*
A possible symptom is that, after turning the opener’s power off and back on, the door operates normally for approximately two or three seconds when the wall switch is pressed, but then suddenly stops.
If you still experience this symptom after repairing the main circuit board, check and consider replacing the motor run capacitor.
Safety warning: Motor capacitors can retain an electrical charge even after the opener has been unplugged. Do not touch the terminals until the capacitor has been safely discharged and verified with appropriate test equipment. If you are not confident doing this, ask a qualified technician or electrician for assistance.


2. Poor Connection at the Travel or Motor-Speed Sensor
I am not certain of the component’s official name, but it appears to be a sensor that monitors the motor’s rotation or the movement of the door.
As shown in the picture below, four wires from this sensor connect to the main circuit board through a plug. In some cases, I found poor solder joints or broken connections in these wires, particularly in the area marked in red.
The symptoms of a poor sensor connection can be very similar to those of a faulty motor run capacitor. The opener may initially appear to operate normally, but then stop suddenly after a few seconds. It may remain unresponsive until its power has been switched off and back on.
If your opener shows these symptoms, inspect the four-wire connector, the cable connections and the solder joints marked in the picture. Look for loose wires, broken conductors, corrosion or cracked solder joints.
Always unplug the opener before inspecting or repairing any internal wiring or components.